Arma-Chek Silver
The brilliant precovered ArmaFlex insulation designed for fast installation, durability and easy cleaning
Technical information Arma-Chek Silver
Material type
Highly flexible, closed-cell elastomeric foam mate
Covering: double layer of aluminium laminate, coat
Property | Value / Assessment | Standard / Test method | ||||||
---|---|---|---|---|---|---|---|---|
Temperature range | ||||||||
Service temperature1,2 |
| EN 14304, EN 14706, EN 14707 | ||||||
Thermal conductivity | ||||||||
Remarks | Depends on ArmaFlex substrate. | EN ISO 13787, EN 12667, EN ISO 8497 | ||||||
Fire Performance and Approvals | ||||||||
Reaction to fire | Arma-Chek Silver (AF) tubes D(L)-s3,d0
Arma-Chek Silver (AF) sheets 13 - 25 mm D-s3,d0 Arma-Chek Silver (AF) sheets 32 - 50 mm D-s3,d0 Arma-Chek Silver (ACE) tubes and sheets E | EN 13823, EN ISO 11925-2 | ||||||
Resistance to water vapour | ||||||||
Water vapour diffusion resistance factor | sheets and tubes μ ≥ 15.000 | EN 13469, EN 12086 | ||||||
Physical attributes | ||||||||
Thickness | approx. 230 μm (covering) | EN 22286 | ||||||
Dimensions and tolerances | In acc. with EN 14304, Table 1 (ArmaFlex substrate) | EN 822, EN 823, EN 13467 | ||||||
Mechanical properties | ||||||||
Tear strength | MD 70 N CD 28 N | EN ISO 527-3 | ||||||
Resistance to mechanical impact | Good puncture and tear resistance. | |||||||
Weather and UV resistance | ||||||||
UV resistance3 | Excellent | EN ISO 4892-2 | ||||||
Health and environment | ||||||||
Health aspects | Dust- and fibre-free. | |||||||
Other technical features | ||||||||
Shelf life | Tape, sheets, tubes, self-adhesive: 1 year | |||||||
Storage | Can be stored in dry, clean rooms at normal relative humidity (50% to 70%) and ambient temperature (0 °C – 35 °C). | |||||||
1When there are fluctuations in temperature, the surface may wrinkle slightly, as elastomeric products expand and contract in these circumstances. However, these superficial changes do not have any impact on the performance of the material. The wrinkles usually disappear as soon as the plant is heated to its original operating temperature. 2For temperatures below -30 °C or above +100 °C, please consult our Customer Service Centre for further information. 3In outdoor applications the colour may fade. This does not have any impact on the functionality of the covering or the insulation material. |