Product_Header_1920x384_ArmaSound

ArmaSound Barrier H

Mass loaded noise barrier engineered for applications with metal jacketing

Technical information ArmaSound Barrier H
Product_pdpimage_800x800_ArmaSound_Barrier_H

Material type

  • Vinyl sound barrier mat. Thermoplastic polymer com

Special features

  • Does not contain lead, unrefined aromatic oils and bitumen.
PropertyValue / AssessmentStandard / Test method
Temperature range
Service temperature1
Min. °CMin. °FMax. °CMax. °F
-20-493185
Fire performance
Practical fire behaviourSelf-extinguishing, burn rate (flame progression) < 100 mm/min.FMVSS 302
Physical attributes
Mass per unit area2mm: 4.8 to 5.50 kg/m² (0,98 to 1.13 lb/ft²)
3mm: 7.2 to 8.25 kg/m² (1.47 to 1.69 lb/ft²)
4mm: 9.7 to 11.0 kg/m² (1.99 to 2.25 lb/ft²)
Mechanical properties
Tensile strength≥ 1.8 MPa (≥ 261 psi)ISO 372
Elongation≥ 25%ISO 372
Acoustic performance
System acoustic insertion lossWhen used with metal cladding and approved non-Armacell acoustic insulation:
ArmaSound Barrier H complies to ISO 15665 Classes A, B and C and Shell DEP 31.46.00.31 - Gen Class D.
ASTM E1222, ISO 15665, ISO 3741
Other technical features
Application conditions4,5Application temperature: +5 to +35°C (+41 to 95°F)
Max. relative humidity: 80%
Shelf life6Max. 3 years
StorageMaterial shall be stored indoors, in clean and dry conditions, away from direct sunlight.

1Intermittent maximum operating temperature. Continuous maximum operating temperature +65°C. For further information, please contact technical customer service.

2Type 1 dumb-bell test piece. Maximum specimen thickness according to the test standard is 3mm.

3Nominal values.

4Application temperature refers to the ambient temperature during installation and the surface temperature of the substrate (e.g. ArmaClad Arma-Chek R covering) to which the product is installed.

5For environmental conditions outside the given range, please contact Technical Services.