Armacell - AP Coilflex - General Info / AP Coilflex - Conformable Duct Liner

AP Coilflex - Conformable Duct Liner

For factory application. Fiber-free, mold resistant.
» Soft elastomeric foam easily conforms to fabricated corners
»Engineered for sheet metal shops
»Cost-effective alternative, half the hand labor (cutting)
»Fiber free and noise reducing
»Water-based adhesives compatible



Duct Liner
AP Coilflex Duct Liner is engineered for automated applications with water-based adhesives in accordance with SMACNA pinning and spacing guidelines, or unpinned applications using an Armaflex 520 Adhesive. Available in rolls in a range of widths including 59" and 60", in 1" thickness (or 1/2" special order).

» Practical: Easily conforms to fabricated duct corners without stiffness or compression, cuts easier and faster
»Mold Resistant: Made with Microban antimicrobial product protection
»Indoor Air Quality: Fiber-free, formaldehyde-free, low VOC's, non-particulating
»Plenum rated: Safe for institutional air ducts, meets NFPA standards
»Noise blocking and vibration dampening
Description
AP Coilflex Duct Liner is a highly conformable, pliable elastomeric thermal insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. The Microban® antimicrobial protection is registered by the Environmental Protection Agency for use in air ducts (EPA Reg. No. 1258-840-42182). It is added during manufacturing to provide an extra level of defense to the natural mold resistance of AP Coilflex.

AP Coilflex is effective for reducing HVAC noise.

It is supplied in rolls 46", 47", 48", 56-1/4", 59" and 60" wide, in 1" (or 1/2" special order) thicknesses. It can be applied with current water-based adhesives and pinning per SMACNA requirements or unpinned using Armaflex 520 Adhesives.
Approvals and Compliance
AP Coilflex Duct Liner meets requirements of NFPA 90A and 90B for Duct Coverings and Linings, and UL 181 for Mold Growth. Approved for use in air plenums, conforms to ASTM C 1534 requirements and withstands temperatures of 250oF.

Like all AP Armaflex insulation, AP Coilflex meets requirements of International Energy Conservation Code (IECC) and ASHRAE for R-Value 4.2 at 1" thickness.

Uses and Applications
AP Coilflex Duct Liner, like AP Armaflex Duct Liners is ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control and resistance to moisture, damage or heat gain. They also reduce noise generated by fans and air movements as well as the rattle or popping of sheet metal air ducts. Coilflex is especially effective factory-applied, including on automated coiling lines, for end use in areas like schools, hospitals, hotels, commercial and public buildings.
Features/Benefits
  • Conformable nonfibrous structure
  • Nondusting
  • Longer life
  • Won't contribute to air quality problems
  • Made with Microban antimicrobial product protection
  • Resists mold on the insulation
  • EPA registered for use in air duct insulation
  • Noise reducing, higher-density material
  • More productive work environment
  • Reduces or blocks HVAC noise
  • Helps prevent metal duct vibration, sound transfer
  • Smooth surface that reduces dirt and debris accumulation
  • Inhibits amplification of biological contaminants
  • Basis for continuing system hygiene
  • Elastomeric foam
  • Fiber free
  • Resistant to incidental damage
  • No special tools; no dust mask required during fabrication and installation
  • Inherent vapor retarder
  • Requires no mastics
  • Competitive total installed cost
ALL ARMACELL FACILITIES IN NORTH AMERICA ARE ISO 9001:2000 CERTIFIED


Related information
Product Technical Information
Material Safety Data Sheet
Product Range
AP Coilflex Technique
Date of Release: print friendly page
All data is valid for the application of our products in USA and Canada and Mexico.

Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell's own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice.

Armacell LLC · 7600 Oakwood Street Ext. · Mebane, NC 27302 · tel 919 304-3846 · fax 919 304-3720 · email: info.us@armacell.com · website: www.armacell.us

© Armacell LLC